MEL ITEM
MEL ITEM — ONE MAIN FUEL PUMP INOP
LOFT SCENARIO 1 · SBSP → SBGR
MEL 28-22-01
MAIN TANK BOOST PUMPS
Category
C
Installed
4
Required
3
One Main Tank Boost Pump may be inoperative provided:
- The inoperative pump is deactivated.
- Appropriate minimum fuel quantities are maintained in the associated tank.
Exception
EXCEPT FOR ETOPS BEYOND 120 MINUTES
AFT PUMP INOPERATIVE
Minimum fuel in EACH main tank
Takeoff
7,500
lb
3,402 kg
Landing
2,500
lb
1,134 kg
FORWARD PUMP INOPERATIVE
Minimum fuel in EACH main tank
Takeoff
4,800
lb
2,177 kg
Landing
1,800
lb
817 kg
Quick Memory
AFT PUMP·TO 7,500 lb → LDG 2,500 lb
FWD PUMP·TO 4,800 lb → LDG 1,800 lb